4.6 Article

Host reaction to vaginally inserted collagen containing polypropylene implants in sheep

期刊

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.ajog.2014.11.008

关键词

biomechanics; collagen; contractility; mesh; sheep

资金

  1. European Commission
  2. Marie Curie Industria-Academia Partnership Program grant [251356]
  3. FP7 project BIPUpy (NMP) [Large-310389]
  4. Fonds Wetenschappelijk Onderzoek Vlaanderen [1801207N]
  5. Johnson & Johnson Medical (Norderstedt, Germany)
  6. FEG Textil technik (Aachen, Germany)
  7. Blasingame, Burch, Garrard, and Ashley (Atlanta, GA)

向作者/读者索取更多资源

OBJECTIVE: We aimed to characterize the effect of vaginal or abdominal mesh insertion and of different collagen augmentation of polypropylene mesh in a sheep model. Outcome measures were passive and active biomechanical properties and semiquantitative morphometry. STUDY DESIGN: Forty-two Texel sheep were used: 6 were non-implanted controls (n = 6), the rest were implanted with polypropylene mesh (n = 12; Avaulta Solo; Bard Medical, Covington, GA) or collagencoated meshes: Avaulta Plus (n = 12; Bard Medical) and Ugytex (n = 12; Sofradim International, Trevoux, France). Through a single incision, the rectovaginal septum was dissected and a 35 x 35-mm mesh was sutured to the underlying tissues. Abdominally, a 50 x 50-mm mesh was laid over a primarily sutured full thickness 40-mm longitudinal incisional defect. Animals were explanted after 60 or 180 days (n = 6 per group). Outcome measures were passive biomechanics by biaxial tensiometry, active contractility of vaginal explants, and histologic evidence. RESULTS: Vaginal explants were 2.4 times stiffer compared with native vaginal tissue (P <.001), but without differences in comfort zone stiffness or slope of the load-elongation in the physiologic range between the products that were tested. Collagen coating was associated with a 16-fold reduction in contractile force at 180 days, compared with native vaginal tissue, both for Avaulta Plus (P = .032) and Ugytex (P = .015). Abdominal explants were 1.3-times stiffer compared with native abdominal wall tissue (P <.001) and were 1.9-times stiffer compared with vaginal explants. CONCLUSION: Vaginal mesh implantation yields less stiff explants compared with abdominal explants. Vaginal mesh implantation also alters the passive and active biomechanical properties compared with native vaginal tissues. Collagen matrices did not reduce the number of graft-related complications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据