4.1 Article

Work of breathing for cuffed and uncuffed pediatric endotracheal tubes in an invitro lung model setting

期刊

PEDIATRIC ANESTHESIA
卷 28, 期 9, 页码 780-787

出版社

WILEY
DOI: 10.1111/pan.13430

关键词

cuffed vs uncuffed endotracheal tubes; inspiratory airway pressure; work of breathing

向作者/读者索取更多资源

BackgroundOver the last decade, cuffed endotracheal tubes are increasingly used in pediatric anesthesia and also in pediatric intensive care. However, the smaller inner diameter of cuffed endotracheal tubes and, implicitly, the increased endotracheal tube resistance is still a matter of debate. AimsThis invitro study investigated work of breathing and inspiratory airway pressures in cuffed and uncuffed endotracheal tubes and the impact of pressure support ventilation and automatic tube compensation. MethodsIn 5 simulated neonatal and pediatric lung models, the Active Servo Lung 5000 and an intensive care ventilator were used to quantify the differences in work of breathing under spontaneous breathing (with and without pressure support ventilation and automatic tube compensation) between cuffed and uncuffed endotracheal tubes. Additionally, differences in inspiratory airway pressures, measured either proximal or distal of the endotracheal tube, between cuffed and uncuffed endotracheal tubes under mechanical ventilation were investigated. ResultsWork of breathing was overall 10.27% [95% confidence interval 9.01-11.94] higher with cuffed than with uncuffed endotracheal tubes and was dramatically reduced by 34.19% [95% confidence interval 31.61-35.25] with the application of pressure support. Automatic tube compensation almost diminished work of breathing differences between the 2 endotracheal tube types in nearly all pediatric lung models. Peak inspiratory and mean airway pressures measured at the proximal endotracheal tube end revealed significantly higher values in cuffed than in uncuffed endotracheal tubes. However, these differences measured at the distal end of the endotracheal tube became minimal. ConclusionThis invitro study confirmed significant differences in work of breathing and inspiratory pressures between cuffed and uncuffed endotracheal tubes. Work of breathing, however, is almost neutralized by pressure support ventilation with automatic tube compensation and distal inspiratory airway pressures that, from a clinical perspective, are not significantly increased.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据