4.3 Article

Differences in trochlear parameters between native and prosthetic kinematically or mechanically aligned knees

期刊

出版社

ELSEVIER MASSON, CORPORATION OFFICE
DOI: 10.1016/j.otsr.2017.10.009

关键词

Kinematic alignment; Total knee arthroplasty; Trochleae; Stuffing

资金

  1. Uren Foundation
  2. Sackler Trust
  3. ORUK
  4. Academy of Medical Sciences (AMS) [SGL014\\1007] Funding Source: researchfish
  5. National Institute for Health Research [CL-2013-21-013] Funding Source: researchfish

向作者/读者索取更多资源

Introduction: Kinematic (KA) and mechanical (MA) alignment techniques are two different philosophies of implant positioning that use the same TKA implants. This might generate differences in the resulting prosthetic trochleae parameters between the two techniques of alignment. Our study aim was to test the following hypotheses : (1) mechanically or kinematically aligned femoral implant understuffs the native trochlear articular surface and poorly restores the native groove orientation, and (2) the orientation of the prosthetic trochlear groove and trochlear fill are different between MA and KA. Methods: Three-dimensional models of the femur were made from segmentation of preoperative Magnetic Resonance Imaging scans (MRIs) of ten subjects with isolated medial tibiofemoral osteoarthritis. In-house planning and analysis software kinematically and mechanically aligned a modern cruciate retaining femoral component and determined differences in parameters of the trochlear fit between native and prosthetic trochleae, and between KA and MA prosthetic trochleae. Results: The MA prosthetic trochleae did not fill (understuffed) the entire length of the native medial facet and the proximal 70% of the native groove and lateral facet, and oriented the trochleae groove 8 degrees more valgus than native. The KA prosthetic trochleae understuffed the proximal 70% of the native trochleae, and had a groove 6 degrees more valgus than native. The KA trochleae understuffed the medial facet distally and oriented the groove 2 degrees less valgus and 3 degrees more internally rotated than the MA trochleae. Conclusion: MA and KA prosthetic trochleae substantially understuff and create a prosthetic groove more valgus compared to native trochlear anatomy, and they also differed between each other regarding trochleae stuffing and groove alignment. Although randomized trials have not shown differences in patellofemoral complications between KA and MA, a femoral component designed specifically for KA that more closely restores the native trochlear anatomy might improve patient reported satisfaction and function. Level of evidence: Level 2 controlled laboratory study. (c) 2017 Elsevier Masson SAS. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据