4.5 Article

Simultaneous measurement of refractive index and temperature based on down-taper and thin-core fiber

期刊

OPTICS COMMUNICATIONS
卷 426, 期 -, 页码 506-510

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.optcom.2018.06.004

关键词

Mach-Zehnder interferometer; Down-taper; Thin-core fiber; Refractive index; Temperature

类别

资金

  1. State Key Laboratory on Integrated Optoelectronics of China [IOSKL2015KF06]
  2. Tianjin Science and Technology Development Fund for Colleges and Universities [20140708]

向作者/读者索取更多资源

A Mach-Zehnder interferometer (MZI) based on the cascaded structure of a single-mode fiber (SMF) down-taper and thin-core fiber (TCF) is proposed and experimentally demonstrated. The down-taper acts as mode coupler to excite cladding modes. The extinction ratio of the transmission spectra can reach up to 20dB. By monitoring the wavelength shifts of interference dip1 and dip2, simultaneous measurement of refractive index (RI) and temperature can be achieved. The experimental results show that the wavelengths at interference dip1 and dip2 have blue shifts with the increase of RI and red shifts with the increase of temperature. The RI sensitivities at interference dip1 and dip2 are -30.290 nm/RIU and -79.335nm/RIU, respectively. The temperature sensitivities at interference dip1 and dip2 are 0.065 nm/degrees C and 0.053 nm/degrees C, respectively. The proposed MZI exhibits the advantages of easy fabrication, high extinction ratio, low cost, and simultaneous measurement of RI and temperature, which will make a significant contribution to RI measurement

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据