First clinical implementation of real-time, real anatomy tracking and radiation beam control

期刊

MEDICAL PHYSICS
卷 45, 期 8, 页码 3728-3740

出版社

WILEY
DOI: 10.1002/mp.13002

关键词

gating; image-guided therapy; MRI; quality assurance

向作者/读者索取更多资源

PurposeWe describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. MethodsThe system utilizes real-time cine imaging capabilities at 4 frames per second for real-time tracking and beam control. Testing of the system was performed using an in-house developed motion platform and a commercially available motion phantom. Anatomical tracking is performed by first identifying a target (a region of interest that is either tissue to be treated or a critical structure) and generating a contour around it. A boundary contour is also created to identify tracking margins. The tracking algorithm deforms the anatomical contour (target or a normal organ) on every subsequent cine frame and compares it to the static boundary contour. If the anatomy of interest moves outside the boundary, the radiation delivery is halted until the tracked anatomy returns to treatment portal. The following were performed to validate and clinically implement the system: (a) spatial integrity evaluation; (b) tracking accuracy; (c) latency; (d) relative point dose and spatial dosimetry; (e) development of clinical workflow for gating; and (f) independent verification by an outside credentialing service. ResultsThe spatial integrity of the MR system was found to be within 2mm over a 45-cm diameter field-of-view. The tracking accuracy for geometric targets was within 1.2mm. The average system latency was measured to be within 394ms. The dosimetric accuracy using ionization chambers was within 1.3%1.7%, and the dosimetric spatial accuracy was within 2mm. The phantom irradiation for the outside credentialing service had satisfactory results, as well. ConclusionsThe first clinical MR-IGRT system was validated for real-time tracking and gating capabilities and shown to be reliable and accurate. Patient workflow methods were developed for efficient treatment. Periodic quality assurance tests can be efficiently performed with commercially available equipment to ensure accurate system performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据