The relative biological effectiveness for carbon, nitrogen, and oxygen ion beams using passive and scanning techniques evaluated with fully 3D silicon microdosimeters

期刊

MEDICAL PHYSICS
卷 45, 期 5, 页码 2299-2308

出版社

WILEY
DOI: 10.1002/mp.12874

关键词

heavy ion therapy; microdosimetry; MKM; RBE; silicon on insulator

资金

  1. Australian Government through the Australian Research Council [DP 170102273]
  2. Norwegian Research Council

向作者/读者索取更多资源

BackgroundThe aim of this study was to measure the microdosimetric distributions of a carbon pencil beam scanning (PBS) and passive scattering system as well as to evaluate the relative biological effectiveness (RBE) of different ions, namely C-12, N-14, and O-16, using a silicon-on-insulator (SOI) microdosimeter with well-defined 3D-sensitive volumes (SV). Geant4 simulations were performed with the same experimental setup and results were compared to the experimental results for benchmarking. MethodTwo different silicon microdosimeters with rectangular parallelepiped and cylindrical shaped SVs, both 10 m in thickness were used in this study. The microdosimeters were connected to low noise electronics which allowed for the detection of lineal energies as low as 0.15 keV/m in tissue. The silicon microdosimeters provide extremely high spatial resolution and can be used for in-field and out-of-field measurements in both passive scattering and PBS deliveries. The response of the microdosimeters was studied in 290 MeV/u C-12, 180 MeV/u N-14, 400 MeV/u O-16 passive ion beams, and 290 MeV/u C-12 scanning carbon therapy beam at heavy ion medical accelerator in Chiba (HIMAC) and Gunma University Heavy Ion Medical Center (GHMC), Japan, respectively. The microdosimeters were placed at various depths in a water phantom along the central axis of the ion beam, and at the distal part of the Spread Out Bragg Peak (SOBP) in 0.5 mm increments. The RBE values of the pristine Bragg peak (BP) and SOBP were derived using the microdosimetric lineal energy spectra and the modified microdosimetric kinetic model (MKM), using MKM input parameters corresponding to human salivary gland (HSG) tumor cells. Geant4 simulations were performed in order to verify the calculated depth-dose distribution from the treatment planning system (TPS) and to compare the simulated dose-mean lineal energy to the experimental results. ResultsFor a 180 MeV/u N-14 pristine BP, the dose-mean lineal energy (yD) over bar obtained with two types of silicon microdosimeters started from approximately 29 keV/mu m at the entrance to 92 keV/mu m at the BP, with a maximum value in the range of 412 to 438 keV/mu m at the distal edge. For 400 MeV/u O-16 ions, the dose-mean lineal energy (yD) over bar started from about 24 keV/mu m at the entrance to 106 keV/mu m at the BP, with a maximum value of approximately 381 keV/m at the distal edge. The maximum derived RBE10 values for N-14 and O-16 ions were found to be 3.10 0.47 and 2.93 +/- 0.45, respectively. Silicon microdosimetry measurements using pencilbeam scanning C-12 ions were also compared to the passive scattering beam. ConclusionsThese SOI microdosimeters with well-defined three-dimensional (3D) SVs have applicability in characterizing heavy ion radiation fields and measuring lineal energy deposition with sub-millimeter spatial resolution. It has been shown that the dose-mean lineal energy increased significantly at the distal part of the BP and SOBP due to very high LET particles. Good agreement was observed for the experimental and simulation results obtained with silicon microdosimeters in N-14 and O-16 ion beams, confirming the potential application of SOI microdosimeter with 3D SV for quality assurance in charged particle therapy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据