3.8 Proceedings Paper

Causes analysis of wet flue gas desulphurization stack rainout for the thermal powerplant without GGH and its countermeasures

期刊

APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2
卷 724-725, 期 -, 页码 1306-1309

出版社

TRANS TECH PUBLICATIONS LTD
DOI: 10.4028/www.scientific.net/AMR.724-725.1306

关键词

wet flue gas desulphurization; GGH; rainout; stack; thermal power plant

向作者/读者索取更多资源

This paper introduces the phenomenon of stack rainout in the wet flue gas desulphurization system for the thermal power plant units without GGH,analyzes the factors affecting rainout of wet stack and finds out the main causes resulting in stack rainout of wet flue gas desulphurization for Wangtan Power Plant without GGH,such as low temperature after the flue gas desulfurization, insufficient diffusion capability of flue gas flow, the blockage of mist eliminator, poor operation of electrostatic precipitator, inadequate combustion of boiler, high speed of flue gas flow in the stack, the effect of climate. Also it is analyzed that the mist eliminator equipment and ensuring the efficient operation of electrostatic precipitator may relieve the phenomenon of stack rainout.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据