期刊
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS
卷 77, 期 -, 页码 24-33出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.jmbbm.2017.08.037
关键词
Monotonic indentation; Traumatic brain injury; Rate dependent behavior; Finite element modeling
Viscoelastic properties of the white matter brain tissue are systematically studied in this paper utilizing indentation experiments, mathematical modeling, and finite element simulation. It is first demonstrated that the internal stiffness of the instrument needs to be thoroughly obtained and incorporated in the analysis as its contribution to the recorded mechanical response is significant for experiments on very compliant materials. The flat-punch monotonic indentation is then performed indirectly on sagittal plane slices with pushing a large rigid coverslip into the sample surface. The recorded load and displacement data are used for calibrating different viscoelastic models and presenting numerical values for the model elements. Consequently, the accuracy of the findings based on the theoretical models is investigated by performing finite element simulations which suggest a considerable substrate effect that causes violation of the semi-infinite half-space assumption in modeling of the material behavior. Accordingly, correction factors for adjusting the viscoelastic constants are obtained and presented. Since the Maxwell model shows a superior capability in rendering the mechanical response of the brain, an extension of this model to Multimode Maxwell viscoelastic solid is proposed for modeling the tissue behavior under a more complex load-hold-unload indentation cycle that shows acceptable agreement with experimental observations.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐