3.8 Proceedings Paper

Facade fire tests - measurements and modeling

出版社

E D P SCIENCES
DOI: 10.1051/matecconf/20130902003

关键词

-

向作者/读者索取更多资源

In two recent papers [1, 2] the fire dynamics in a test rig for facade constructions according to the test method SP Brand 105 [3, 4] was investigated both experimentally and numerically. The experimental setup simulates a three-story apartment building (height 6.7 m, width 4m and depth 1.6 m), with external wall-cladding and a room fire at the base. The numerical model was developed in the CFD program Fire Dynamics Simulator (FDS) [5] with analogous geometry and instrumentation. The general features of the fire test were well reproduced in the numerical model however temperatures close to the fire source could not be properly accounted for in the model. In this paper the bi-directional probe measurements are elaborated on and the test used in Ref. [1] is revisited using different heat release rates in the numerical model. The velocity of the hot gases along the facade was well reproduced by the simulations although some deviations were found.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据