3.8 Article

Ultrasonographic Findings of Superficial Radial Nerve and Cephalic Vein

期刊

ANNALS OF REHABILITATION MEDICINE-ARM
卷 38, 期 1, 页码 52-56

出版社

KOREAN ACAD REHABILITATION MEDICINE
DOI: 10.5535/arm.2014.38.1.52

关键词

Radial nerve; Forearm; Ultrasonography

向作者/读者索取更多资源

Objective To investigate the anatomic relationship between the superficial radial nerve (SRN) and the cephalic vein (CV) through ultrasonography due to the possibility of SRN injury during cephalic venipuncture. Methods Both forearms of 51 healthy volunteers with no history of trauma or surgery were examined in proximal to distal direction using ultrasonography. We measured the distance between the radial styloid process (RSP) and the point where the SRN begins contact with the CV, and measured the distance between the RSP and the point where the SRN is separated from the CV. The point where the SRN penetrates the brachioradialis fascia was also evaluated. Results The SRN came in contact with the CV at a mean of 9.35 +/- 1.05 cm from the RSP and separated from the CV at a mean of 6.29 +/- 1.17 cm from the RSP. The SRN pierced the brachioradialis fascia at a mean of 10.31 +/- 0.89 cm from the RSP and horizontally 1.35 +/- 0.36 cm medial to the radius margin. All parameters had no significant differences in gender or direction. Conclusion The SRN had close approximation to the CV in the distal second quarter of the forearm. We recommend for cephalic venipuncture to be avoided in this area, and, if needed, it should be carried out with care not to cause injury to the SRN.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据