4.5 Article

Simultaneous analysis of multiple urinary biomarkers for the evaluation of oxidative stress by automated online in-tube solid-phase microextraction coupled with negative/positive ion-switching mode liquid chromatography-tandem mass spectrometry

期刊

JOURNAL OF SEPARATION SCIENCE
卷 41, 期 13, 页码 2743-2749

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.201800175

关键词

biomarkers; in-tube solid-phase microextraction; liquid chromatography; reactive oxygen species; tandem mass spectrometry

资金

  1. [26460053]

向作者/读者索取更多资源

This study described an automated online method for the simultaneous determination of 8-isoprostane, 8-hydroxy-2'-deoxyguanosine, and 3-nitro-L-tyrosine in human urine. The method involves in-tube solid-phase microextraction using a Carboxen 1006 PLOT capillary column as an extraction device, followed by liquid chromatography with tandem mass spectrometry using a CX column and detection in the negative/positive switching ion-mode by multiple reaction monitoring. Using their stable isotope-labeled internal standards, each of these oxidative stress biomarkers showed good linearity from 0.02 to 2.0 ng/mL. Their detection limits (S/N = 3) were 3.421.5 pg/mL, and their intra- and inter-day precisions (relative standard deviations) were >3.9 and 6.5% (n = 5), respectively. This method was applied successfully to the analysis of urine samples, without any other pretreatment and interference peaks.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据