4.6 Article

Development and validation of a sensitive and rapid UHPLC-MS/MS method for the simultaneous quantification of the common active and inactive metabolites of vicagrel and clopidogrel in human plasma

期刊

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2017.11.019

关键词

Vicagrel; Clopidogrel; Active metabolite; LC-MS/MS; Human plasma; P2Y(12) inhibitor

向作者/读者索取更多资源

Vicagrel, an analog of clopidogrel, is a novel thienopyridine P2Y(12) antagonist in clinical development in China for the treatment of acute coronary syndromes. Vicagrel and clopidogrel are prodrugs requiring metabolic activation to produce a pharmacologically active thiol metabolite (H4) in vivo. The formation of H4 from vicagrel in humans is promising more efficient and consistent than that from clopidogrel. After oral dosing of vicagrel or clopidogrel to humans, the active thiol metabolite H4 and two inactive metabolites closely related to H4 formation (the thiol metabolite H3 and the S-methylated metabolite SM3) were observed in plasma; SM3 was the most abundant drug-related component of vicagrel in circulation. In this study, a sensitive, rapid, and reliable UHPLC-MS/MS method was developed for the simultaneous determination of derivatized H3 (MP-H3), derivatized H4 (MP-H4), and SM3 in human plasma to investigate the pharmacokinetics of vicagrel in healthy subjects compared with clopidogrel. After extracted from 50 mu L of plasma by simple protein precipitation, the analytes and stable isotope-labeled internal standards were separated on an Acquity UPLC BEH C-18 column (100 mm x 2.1 mm, 1.7 mu m). The mobile phase was acetonitrile-water-formic acid (45:55:0.0275, v/v/v) delivered at a flow rate of 0.45 mL/min under isocratic elution. The total chromatographic run time was 6 min. MP-H3, MP-H4, and SM3 were separated from their corresponding isomers under the chromatographic conditions. Mass spectrometric detection was conducted in multiple reaction monitoring mode on an AB Sciex Qtrap 5500 System using a positive electrospray ionization interface. The calibration curves were linear in the following ranges: 0.100-200 ng/mL for MP-H3 and MP-H4 and 1.00-1000 ng/mL for SM3. The intra- and inter-day accuracy and precision for each analyte at all concentrations were within acceptable limits (+/- 15%). The validated method was successfully applied to compare the pharmacokinetics of vicagrel and clopidogrel after a single oral administration to healthy subjects in the first-in-human study of vicagrel. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据