4.5 Article

Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy

期刊

JOURNAL OF NEURO-ONCOLOGY
卷 137, 期 2, 页码 429-438

出版社

SPRINGER
DOI: 10.1007/s11060-017-2735-y

关键词

Glioblastoma; Intensity-modulated radiation therapy; 3D conformational radiation therapy; Dosimetric outcomes; Clinical outcomes

向作者/读者索取更多资源

We aimed to compare three-dimensional conformal radiotherapy (3D-CRT) with intensity-modulated radiotherapy (IMRT) for the treatment of glioblastoma. Retrospective study of 220 patients with glioblastoma, treated with 3D-CRT or IMRT, with or without surgery. Dosimetric parameters as well as clinical and survival data for the two techniques were analyzed and compared. The median conformity index was 1.53 (range 0-2.69) for 3D-CRT and 1.25 (range 0.97-2.01) for IMRT, p < 10(-4). The median homogeneity index was 0.10 (range 0.03-0.32) for 3D-CRT and 0.07 (range 0.03-0.18) for IMRT, p < 10(-4). There were significantly fewer acute grade 1 and 2 neurological toxicities in the IMRT group especially for edema (1.3 versus 12.4%, p = 0.017), concentration disorders (6.6 versus 19.9%, p = 0.003) and consciousness disorders (2.6 versus 13.2%, p = 0.002) although IMRT patients had a significantly worse pre-treatment neurological status than 3D-CRT patients. Median survival was 16.0 months (range 11.9-17.8) for IMRT and 13.4 months (range 11.7-15.7) for 3D-CRT patients (p = 0.542). IMRT improved target conformity and reduced neurological toxicities for patients with glioblastomas.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据