4.7 Article

Separating precipitation and evapotranspiration from noise - a new filter routine for high-resolution lysimeter data

期刊

HYDROLOGY AND EARTH SYSTEM SCIENCES
卷 18, 期 3, 页码 1189-1198

出版社

COPERNICUS GESELLSCHAFT MBH
DOI: 10.5194/hess-18-1189-2014

关键词

-

资金

  1. Deutsche Forschungsgemeinschaft (DFG) [WE 1125/29-1, FOR 1736 UCaHS - WE 1125/30-1]

向作者/读者索取更多资源

Weighing lysimeters yield the most precise and realistic measures for evapotranspiration (ET) and precipitation (P), which are of great importance for many questions regarding soil and atmospheric sciences. An increase or a decrease of the system mass (lysimeter plus seepage) indicates P or ET. These real mass changes of the lysimeter system have to be separated from measurement noise (e.g., caused by wind). A promising approach to filter noisy lysimeter data is (i) to introduce a smoothing routine, like a moving average with a certain averaging window, omega, and then (ii) to apply a certain threshold value, delta, accounting for measurement accuracy, separating significant from insignificant weight changes. Thus, two filter parameters are used, namely w and delta. In particular, the time-variable noise due to wind as well as strong signals due to heavy precipitation pose challenges for such noise-reduction algorithms. If w is too small, data noise might be interpreted as real system changes. If w is too wide, small weight changes in short time intervals might be disregarded. The same applies to too small or too large values for delta. Application of constant w and delta leads either to unnecessary losses of accuracy or to faulty data due to noise. The aim of this paper is to solve this problem with a new filter routine that is appropriate for any event, ranging from smooth evaporation to strong wind and heavy precipitation. Therefore, the new routine uses adaptive w and delta in dependence on signal strength and noise (AWAT - adaptive window and adaptive threshold filter). The AWAT filter, a moving-average filter and the Savitzky-Golay filter with constant w and delta were applied to real lysimeter data comprising the above-mentioned events. The AWAT filter was the only filter that could handle the data of all events very well. A sensitivity study shows that the magnitude of the maximum threshold value has practically no influence on the results; thus only the maximum window width must be predefined by the user.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据