4.6 Article

Noninvasive Measurement of Scleral Stiffness and Tangent Modulus in Porcine Eyes

期刊

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
卷 55, 期 6, 页码 3721-3726

出版社

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/iovs.13-13674

关键词

sclera; glaucoma; myopia; tangent modulus; noninvasive measurement

资金

  1. Innovation and Technology Commission of the HKSAR, China [its/362/09]

向作者/读者索取更多资源

PURPOSE. We investigated an indentation technique to measure the scleral stiffness and tangent modulus of porcine eyes. METHODS. The scleral load-displacement responses were measured with a universal testing machine as a function of IOP in 15 porcine eyes ex vivo using a 5-mm diameter cylindrical flat-punch indenter. The scleral radius of curvature and scleral thickness were measured using a DSLR camera (Alpha 900) and a camera-mounted stereomicroscope (M205C), respectively. The relationships between scleral stiffness, tangent modulus, and IOP were examined. RESULTS. The mean local scleral radius of curvature and scleral thickness were 7.86 +/- 0.49 and 1.03 +/- 0.14 mm, respectively. The average scleral stiffness and scleral tangent modulus of porcine eyes were 0.13 +/- 0.02 N/mm and 0.20 +/- 0.04 MPa at 15 mm Hg, respectively. The scleral stiffness and scleral tangent modulus were correlated positively with IOP (scleral stiffness, 0.989 < r < 0.999, P < 0.001; scleral tangent modulus, 0.989 < r < 0.999, P < 0.001). CONCLUSIONS. The scleral indentation technique can provide a noninvasive approach to measure scleral stiffness and tangent modulus.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据