Life cycle assessment of different physical-chemical and biological technologies for biogas desulfurization in sewage treatment plants

期刊

JOURNAL OF CLEANER PRODUCTION
卷 181, 期 -, 页码 663-674

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jclepro.2018.02.018

关键词

Biogas; Life-cycle assessment; Desulfurization; Energy recovery; Economic analysis

资金

  1. Spanish Government [CTM2012-37927-C03]

向作者/读者索取更多资源

Biogas desulfurization can be carried out by physical-chemical or biological technologies. Biological technologies are generally described as more environmentally friendly than physical-chemical techniques, although it is. difficult to find studies in which the associated environmental burdens are compared. Therefore, the aim of the work described here was to perform a life cycle assessment to compare the environmental impact of four common desulfurization technologies for hydrogen sulfide removal from biogas produced in sewage treatment plants. The desulfurization technologies studied were aerobic biotrickling filtration, anoxic biotrickling filtration, caustic chemical scrubbing and adsorption on impregnated activated carbon. The environmental assessment was extended with a Capital Expenditures (CAPEX) and Operational Expense (OPEX) analysis. Furthermore, an extra scenario (no desulfurization with biogas combustion) was compared with biogas desulfurization by aerobic biofiltration coupled to energy valorization (best-case treatment scenario). Results indicate that biological technologies are much more favorable in most environmental impact categories than physical chemical technologies and, as expected, are more favorable than the non-treatment scenario. In all desulfurization technologies the most contributing stage to the total environmental burdens was the daily desulfurization operation. The chemical scrubber was the worst scenario except for the Climate Change. In terms of the Climate Change (carbon dioxide equivalent emission), aerobic and anoxic desulfurization would emit 13.9 and 18.7 kg CO2 kg(-1) S-H2S treated, respectively. The anoxic process could be improved to emit only 7.2 kg CO2 kg(-1) S-H2S treated if the nitrate source was produced in a nitrification reactor built at the sewage treatment plant. Caustic chemical scrubber desulfurization and impregnated activated carbon desulfurization would emit 30.0 and 42.1 kg CO2 kg(-1) S-H2S treated, respectively. To all impact categories, the contribution of sulfur compounds was less than 5%. The aerobic biotrickling filtration had the lower environmental impacts. However, the anoxic biotrickling filtration was the best approach if a nitrification reactor was already on-site. (C) 2018 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据