4.6 Article

Core-shell magnetic molecularly imprinted polymers used rhodamine B hydroxyproline derivate as template combined with in situ derivatization for the specific measurement of L-hydroxyproline

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1532, 期 -, 页码 30-39

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2017.11.053

关键词

L-Hydroxyproline; In situ derivatization; Magnetic molecularly imprinted polymer; Specific extraction; Dairy products

资金

  1. National Natural Science Foundation of China [21775088, 81603286, 21405094, 81303179]
  2. Natural Science Foundation of Qinghai Province of China [2016-ZJ-955]
  3. Open Projects Program of the Key Laboratory of Tibetan Medicine Research of Chinese Academy of Sciences
  4. Open Funds of Key Laboratory of TCM Quality Control Technology of Shandong Academy of Sciences
  5. Experimental Research Project of Qufu Normal University [sj201402]
  6. Foundation of Qufu Normal University [BSQD2012019, BSQD2012023]

向作者/读者索取更多资源

In this work, a novel core-shell magnetic molecularly imprinted polymers (MMIPs) for the measurement of L-Hydroxyproline (Hyp) in dairy products was prepared. The derivative of Hyp using N-hydroxysuccinimidyl rhodamine B ester (RBS) as derivatization reagent was employed as template to prepare RBS-Hyp-MMIPs (Fe3O4@MIPs for RBS-Hyp). A new analytical procedure of in situ derivatization with MMIPs (ISD-MMIPs) has been developed for the specific extraction and determination of Hyp in dairy products by ultra high performance liquid chromatography tandem mass spectrometry. The RBS-Hyp-MMIPs was characterized by fourier transform infrared spectrometer and transmission electron microscopy, and evaluated by adsorption experiments. The adsorption process followed Langumuir adsorption isotherm with maximum adsorption capacity of RBS-Hyp on RBS-Hyp-MMIPs at 96 mg/g. In addition, RBS-Hyp-MMIPs showed a short equilibrium time (15.0 min), rapid magnetic separation (5 s) and high stability (retained 95.3% after six cycles). Under the optimized conditions, good linearity was observed with the limits of detection (S/N > 3) and limits of quantification (S/N >10) at 0.1 and 0.5 ng/mL, respectively. On account of the specific extraction performance of RBS-Hyp-MMIPs, not any interference peak from real sample matrix was observed in the chromatograms of milk powder, liquid milk and milk drink. The proposed procedure was successfully applied for selective determination of Hyp from dairy products with satisfactory validation results, which is of great significance to food safety. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据