期刊
JOURNAL OF BRIDGE ENGINEERING
卷 23, 期 6, 页码 -出版社
ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)BE.1943-5592.0001227
关键词
-
The vibration behavior of a stay cable subjected to abrupt rupture due to lateral force was studied using model experiments. Based on the experimental results, the performance of an existing cable-stayed bridge was studied using numerical analysis in cases where stay cables are abruptly ruptured by lateral force. The experimental results show that the impact force currently recommended is insufficient. The impact force is more affected by the tensile stress of the cable during rupture than by the initial stress. The results of numerical analysis show that the cable-stayed bridge analyzed in this study lacks serviceability performance against losing multiple cables in a collision incident. (C) 2018 American Society of Civil Engineers.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐