4.6 Article

Tuning the pure monoclinic phase of WO3 and WO3-Ag nanostructures for non-enzymatic glucose sensing application with theoretical insight from electronic structure simulations

期刊

JOURNAL OF APPLIED PHYSICS
卷 123, 期 2, 页码 -

出版社

AMER INST PHYSICS
DOI: 10.1063/1.5010826

关键词

-

资金

  1. DST (Government of India) [SR/S2/RJN-21/2012]
  2. DST-SERB Fasttrack Young Scientist [SB/FTP/PS-065/2013]
  3. UGC-UKIERI [UGC-2013-14/005]
  4. BRNS-DAE [37(3)/14/48/2014-BRNS/1502]
  5. DST-SERB [PDF/2016/001002]

向作者/读者索取更多资源

Here, we report the controlled hydrothermal synthesis and tuning of the pure monoclinic phase of WO3 and WO3-Ag nanostructures. Comparative electrochemical nonenzymatic glucose sensing properties of WO3 and WO3-Ag were investigated by cyclic voltammetry and chronoamperometric tests. We observed enhanced glucose sensing performance of WO3-Ag porous spheres as compared to bare WO3 nanoslabs. The sensitivity of the pure WO3 nanoslabs is 11.1 mu A mu M-1 cm(-2) whereas WO3-Ag porous spheres exhibit sensitivity of 23.3 mu A mu M-1 cm(-2). The WO3-Ag porous spheres exhibited a good linear range (5-375 mu M) with excellent anti-interference property. Our experimental observations are qualitatively supported by density functional theory simulations through investigation of bonding and charge transfer mechanism of glucose on WO3 and Ag doped WO3. As the binding energy of glucose is more on the Ag doped WO3 (100) surface compared to the bare WO3 (100) surface and the Ag doped WO3 (100) surface becomes more conducting due to enhancement of density of states near the Fermi level, we can infer that Ag doped WO3 exhibits a better charge transfer media compared to bare WO3 resulting in enhanced glucose sensitivity in consistency with our experimental data. Published by AIP Publishing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据