4.3 Article

Evaluation of sparing organs at risk (OARs) in left-breast irradiation in the supine and prone positions and with deep inspiration breath-hold

期刊

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS
卷 19, 期 4, 页码 195-204

出版社

WILEY
DOI: 10.1002/acm2.12382

关键词

cardiac toxicity; deep inspiration breath-hold; heart dose; LAD dose; left ventricle dose; Lt breast radiation; lung dose; prone position; supine position

向作者/读者索取更多资源

Purpose: To compare doses to organs at risk (OARs) for left-sided whole-breast radiation therapy with comparable planning target volume (PTV) coverage using three techniques: free breathing in a supine position (SFB), deep inspirational breath-hold in a supine position (SDIBH), and free breathing in prone position (PFB). Materials and methods: Thirty-three patients with left-sided early-stage breast cancer underwent CT simulation following SFB, SDIBH, and PFB protocols for whole-breast radiation therapy. One radiation oncologist contoured the breast PTV, heart, left ventricle (LV), and left anterior descending artery (LAD). Treatment plans were optimized using field-in-field technique with the AAA algorithm. Each plan was optimized to provide identical coverage to the PTV such that a reasonable comparison for OAR dosimetry could be evaluated. All plans were prescribed 42.56 Gy in 16 fractions to the left-breast PTV. Results: The mean dose in SFB for the heart, LV, and LAD was 1.92, 3.19, and 21.73 Gy, respectively, which were significantly higher than the mean dose in SDIBH for the heart (1.08 Gy, P <= 0.0001), LV (1.50 Gy, P <= 0.0001), and LAD (6.3 Gy, P <= 0.0001) and in PFB for the heart (0.98 Gy, P <= 0.0001), LV (1.34 Gy, P <= 0.0001), and LAD (6.57 Gy, P <= 0.0001). Similar findings were noted for the cardiac components in SFB for V2.5, V5, V10, V20, and V30 compared with values in SDIBH and PFB. The mean dose for the left lung in PFB was 0.61 Gy that was significantly lower than in SFB (5.63 Gy, P <= 0.0001) and SDIBH (5.54 Gy, P <= 0.0001). Mean dose and dosimetric values for each OAR increased in SFB and SDIBH for patients with a large breast volume compared with values for patients with a small breast volume. Conclusions: SFB results in higher heart, LAD, and LV doses than the other techniques. Both PFB and SDIBH are more advantageous for these OARs irrespective of breast volume. PFB results in significantly lower lung doses than SFB and SDIBH. PFB always provided better results than SFB for the heart, LV, LAD, and lung. This conclusion contrasts with some published studies concluding that the prone position has no benefit for heart sparing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据