4.6 Article

Long-Term Outcomes in Patients With New Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement

期刊

JACC-CARDIOVASCULAR INTERVENTIONS
卷 11, 期 3, 页码 301-310

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2017.10.032

关键词

aortic stenosis; left ventricular ejection fraction; pacemaker; transcatheter aortic valve replacement

资金

  1. Edwards Lifesciences
  2. Fundacion Alfonso Martin Escudero (Madrid, Spain)
  3. Medtronic

向作者/读者索取更多资源

OBJECTIVES This study sought to evaluate the long-term clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR). BACKGROUND Conduction disturbances leading to PPI are common following TAVR. However, no data exist regarding the impact of PPI on long-term outcomes post-TAVR. METHODS This was a multicenter study including a total of 1,629 patients without prior PPI undergoing TAVR (balloon-and self-expandable valves in 45% and 55% of patients, respectively). Follow-up clinical, echocardiographic, and pacing data were obtained at a median of 4 years (interquartile range: 3 to 5 years) post-TAVR. RESULTS PPI was required in 322 (19.8%) patients within 30 days post-TAVR (26.9% and 10.9% in patients receiving self-and balloon-expandable CoreValve and Edwards systems, respectively). Up to 86% of patients with PPI exhibited pacing >1% of the time during follow-up (>40% pacing in 51% of patients). There were no differences between patients with and without PPI in total mortality (48.5% vs. 42.9%; adjusted hazard ratio [HR]: 1.15; 95% confidence interval [CI]: 0.95 to 1.39; p = 0.15) and cardiovascular mortality (14.9% vs. 15.5%, adjusted HR: 0.93; 95% CI: 0.66 to 1.30; p = 0.66) at follow-up. However, patients with PPI had higher rates of rehospitalization due to heart failure (22.4% vs. 16.1%; adjusted HR: 1.42; 95% CI: 1.06 to 1.89; p = 0.019), and the combined endpoint of mortality or heart failure rehospitalization (59.6% vs. 51.9%; adjusted HR: 1.25; 95% CI: 1.05 to 1.48; p = 0.011). PPI was associated with lesser improvement in LVEF over time (p = 0.051 for changes in LVEF between groups), particularly in patients with reduced LVEF before TAVR (p = 0.005 for changes in LVEF between groups). CONCLUSIONS The need for PPI post-TAVR was frequent and associated with an increased risk of heart failure rehospitalization and lack of LVEF improvement, but not mortality, after a median follow-up of 4 years. Most patients with new PPI post-TAVR exhibited some degree of pacing activity at follow-up. (c) 2018 by the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据