4.5 Article

Electric cautery does not reduce blood loss in primary total knee arthroplasty compared with scalpel only surgery a double-blinded randomized controlled trial

期刊

INTERNATIONAL ORTHOPAEDICS
卷 42, 期 12, 页码 2755-2760

出版社

SPRINGER
DOI: 10.1007/s00264-018-4048-y

关键词

Scalpel; Knife; Electric cautery; Blood loss; Total knee arthroplasty

向作者/读者索取更多资源

Purpose The purpose of this study was to systematically compare blood loss between the electric cautery and scalpel used in primary total knee arthroplasty (TKA). Methods We performed a double-blind trial randomizing osteoarthritic knee patients undergoing unilateral TKA done by either using scalpel (group S) or cautery (group C). Primary outcomes were total blood loss calculated from maximum haemoglobin drop and blood loss collected in drain. Secondary outcomes were systemic inflammatory response (serum C-reactive protein), wound complications, and functional outcomes assessed over three months. Results A total of 80 patients were recruited. Group S had similar calculated total blood loss compared to group C (1070 (S) vs 1128 (C) mL, 95% CI -219 to 103, p = 0.47). There was no difference in the mean drain-collected blood loss between the two groups (443 (S) vs 486 (C) mL, 95% CI -128 to 47, p = 0.36). Group C had higher serum C-reactive protein level at 48 hours after TKA compare to group S (105 vs 140 mg/dL, 95% CI - 66 to -4, p = 0.03). Wound complications and functional outcomes at three months were also similar between the two groups. Conclusions Using electric cautery does not reduce total blood loss as we thought it would be in primary TKA compare to scalpel only surgery and it is also associated with a greater systemic inflammatory response. Cautery used in TKA which operated under tourniquet may not be worthwhile for the risk of hazardous smoke and the increasing cost.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据