4.3 Article

Left and right ventricular parameters corrected with threshold-based quantification method in a normal cohort analyzed by three independent observers with various training-degree

期刊

出版社

SPRINGER
DOI: 10.1007/s10554-018-1322-4

关键词

Cardiac magnetic resonance; Endocardium; Papillary muscles; Trabeculae; Automated thresholding; Cardiac chamber quantification

资金

  1. National Research, Development and Innovation Office (NKFIH) of Hungary [K 120277]
  2. National Research, Development and Innovation Fund of Hungary [NVKP_16-1-2016-0017, NVKP_16]

向作者/读者索取更多资源

While cardiac magnetic resonance (CMR) is the reference method to evaluate left and right ventricular functions, volumes and masses, there is no widely accepted method for the quantitative analysis of trabeculae and papillary muscles (TPM). The aim of this study was to investigate the effect of TPM quantification on left and right ventricular CMR values in a normal cohort and to investigate interobserver variability of threshold-based (TB) analysis by three independent observers with variant experience in CMR. At our clinic, 60 healthy volunteers (30 males, mean age 25.6 +/- 4.7 years) underwent CMR scan performed on a 1.5T Philips Achieva MR machine. On short-axis cine images, endo- and epicardial contours were detected by three independent observers with variable experience in CMR (low- ca. 120, mid- > 800, high-experienced > 5000 original CMR cases). Using Conv and TB methods (Medis 7.6 QMass software Leiden, The Netherland), we measured LV and RV ejection fractions, end-diastolic, end-systolic, stroke volumes and masses. We used TB method for quantifying TPM in ventricles using epicardial contour layers. Interobserver variability was evaluated, and the observer's experience as an impact on variability of each investigated parameters was assessed. Comparing Conv and TB quantification methods' significant difference were detected for all LV and RV parameters in case of all observers (H, M and L p < 0.0001). The global intraclass correlation coefficient (G-ICC) representing interobserver agreement for all investigated parameters was lower with Conv method (G-ICCConv vs. G-ICCTB 0.86 vs. 0.92 p < 0.0001). The ICC of LV parameters was higher using TB quantification (LV-ICCConv vs. LV-ICCTB 0.92 vs. 0.96 p < 0.0001), and for the evaluation of RV values, the TB method also had significantly higher interobserver agreement (RV-ICCConv vs. RV-ICCTB 0.80 vs. 0.89 p < 0.0001). The TB algorithm could be a consistent method to assess LV and RV CMR values, and to measure trabeculae and papillary muscles quantitatively in various level of experience in CMR.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据