4.6 Article

Benefits of left ventricular endocardial pacing comparing failed implants and prior non-responders to conventional cardiac resynchronization therapy: A subanalysis from the ALSYNC study

期刊

INTERNATIONAL JOURNAL OF CARDIOLOGY
卷 259, 期 -, 页码 88-93

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ijcard.2018.01.030

关键词

Heart failure; Cardiac resynchronisation therapy; Left ventricular endocardial pacing; CRT non-responders; Outcome

资金

  1. Medtronic Inc., Mounds View, MN, U.S.

向作者/读者索取更多资源

Objective: Cardiac resynchronisation therapy (CRT) is limited by a substantial proportion of non-responders. Left ventricular endocardial pacing (LVEP) may offer enhanced possibility to deliver CRT in patients with a failed attempt at implantation and to improve clinical status of CRT non-responders. Methods: The ALternate Site Cardiac ResYNChronisation (ALSYNC) study was a prospective, multi-centre cohort study that included 118 CRT patients with a successfully implanted endocardial left ventricular (LV) lead, including 90 failed coronary sinus (CS) implants and 28 prior non-responders who had worsened or unchanged heart failure status after at least 6 months of optimal conventional CRT therapy. Results: Patients were followed for 19 +/- 9 months. At baseline, prior non-responders were sicker as evidenced by a larger LV end-diastolic diameter (70 +/- 12 vs 65 +/- 9 mm, p =. 03) and a trend towards larger LV end-systolic volume index (LVESVi, 95 +/- 51 vs 74 +/- 39 ml/m(2), p =. 07), and were more frequently anti-coagulated (96% vs 72%, p = .008) despite similar history of atrial fibrillation (54% vs 51%, p = .83). At 6 months, LVEP significantly improved LV ejection fraction (2.3 +/- 7.5 and 8.6 +/- 10.0%), New York Heart Association Class (0.4 +/- 0.9 and 0.7 +/- 0.8), LVESVi (9 +/- 16 and 18 +/- 43 ml/m(2)), and sixminute walk test (56 +/- 73 and 54 +/- 92 m) in prior non-responders and failed CS implants, relative to baseline (all p > .05), respectively. LVESVi reduction >= 15% was seen in 47% of the prior non-responder patients and 57% of failed CS patients. Conclusion: These data suggest that a sizable proportion of CRT non-responders can improve by LVEP, though to a lesser extent than failed CS implants. (C) 2018 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据