4.6 Article

Performance Evaluation of CMUT-Based Ultrasonic Transformers for Galvanic Isolation

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TUFFC.2018.2796303

关键词

Acoustic transformer; capacitive micromachined ultrasonic transducer (CMUT); finite-element method (FEM) modeling; galvanic isolation; power switch control

资金

  1. Programme de l'economie numerique des Investissements d'Avenir

向作者/读者索取更多资源

This paper presents the development of a novel acoustic transformer with high galvanic isolation dedicated to power switch triggering. The transformer is based on two capacitive micromachined ultrasonic transducers layered on each side of a silicon substrate; one is the primary circuit, and the other is the secondary circuit. The thickness mode resonance of the substrate is leveraged to transmit the triggering signal. The fabrication and characterization of an initial prototype is presented in this paper. All experimental results are discussed, from the electrical impedance measurements to the power efficiency measurements, for different electrical load conditions. A comparison with a specifically developed finite-element method model is done. Simulations are finally used to identify the optimization rules of this initial prototype. It is shown that the power efficiency can be increased from 35% to 60%, and the transmitted power can be increased from 1.6 to 45 mW/Volt.