4.8 Article

Fast Transistor Open-Circuit Faults Diagnosis in Grid-Tied Three-Phase VSIs Based on Average Bridge Arm Pole-to-Pole Voltages and Error-Adaptive Thresholds

期刊

IEEE TRANSACTIONS ON POWER ELECTRONICS
卷 33, 期 9, 页码 8040-8051

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2017.2773130

关键词

Average bridge arm pole-to-pole (PTP) voltages; error-adaptive thresholds; fault diagnosis; grid-tied three-phase voltage-source inverters (VSI); transistor open-circuit (OC) fault

资金

  1. National Nature Science Foundation of China [51337009]

向作者/读者索取更多资源

This paper presents a model-based method to diagnose single-and multiple-transistor open-circuit (OC) faults in grid-tied three-phase voltage-source inverters (VSIs). The method is based on calculated average bridge arm pole-to-pole (PTP) voltages and error-adaptive thresholds. Only existing signals for closed-loop control are needed; thus, this method can be easily embedded in the system without extra sampling and circuits. Average PTP voltage deviations are chosen as diagnosis variables, which show considerable distinction quickly after fault. Consequently, fast fault diagnosis speed can be achieved. The fault diagnosis time for single fault can be as short as two switching periods. Besides, diagnosis variables show the same faulty characteristics in inverter mode and rectifier mode; thus, this method is effective in both modes. Moreover, for the first time, the variation of inductance caused by conducted current is considered to obtain a more accurate variable-inductance model, and the thresholds are updated according to mathematically estimated diagnosis variable calculation errors from sampling error, inductance error, dead time, and delay time, which maintains high robustness as well as fast speed. Finally, the effectiveness of the proposed method is validated with experiments.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据