4.4 Article

Using Aperture Impedance for Shielding Effectiveness Estimation of a Metallic Enclosure With Multiple Apertures on Different Walls Considering Higher Order Modes

期刊

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TEMC.2017.2738563

关键词

Circuit theory; electromagnetic compatibility; shielding effectiveness; S-parameters

资金

  1. Ferdowsi University of Mashhad [33482]

向作者/读者索取更多资源

In this paper, our previously published analytical method for calculation of shielding effectiveness ( SE) of a metallic enclosure with a centered aperture is extended to generalize the method for a much wider range of applications. The new extended analytic formulation considers an enclosure with centered and off-centered apertures on different enclosure walls and the monitoring point can be anywhere inside the enclosure. In addition, the incident field angle and the polarization angle are arbitrary and higher order modes are considered. An analytic discussion and an experimental setup are proposed for the validation of the new method. The proposed measurement setup can lead to a new SE measurement method for enclosures with arbitrary position apertures. In this measurement method, there is no need for antennas, reverberation chambers, etc. Another advantage of the proposed method is introducing a new figure of merit for shield evaluation. This new figure of merit is S-11 of a two port microstrip line which is placed over the apertures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据