4.6 Article

Heartbeats Based Biometric Random Binary Sequences Generation to Secure Wireless Body Sensor Networks

期刊

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
卷 65, 期 12, 页码 2751-2759

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2018.2815155

关键词

Heartbeats; inter-pulse intervals (IPIs); random binary sequences (RBSs); security; wireless body sensor networks

资金

  1. Guangdong Province Natural Science Fund [2016A030310129]
  2. Guangzhou Science and Technology Planning Project [201704020079]
  3. Shenzhen Governmental Basic Research [JCYJ20170413170301569, JCYJ20160429174426094, JCYJ20150529164154046]
  4. National Natural Science Foundation of China [61771462]
  5. Natural Science Foundation for Distinguished Young Scholars of Guangdong Province, China [2014A030306029]
  6. CAS President's International Fellowship for Visiting Scientists [2017VTA0011]

向作者/读者索取更多资源

Heartbeats based random binary sequences (RBSs) are the backbone for several security aspects in wireless body sensor networks (WBSNs). However, current heartbeats based methods require a lot of processing time (similar to 25-30 s) to generate 128-bit RBSs in real-time healthcare applications. In order to improve time efficiency, a biometric RBSs generation technique using interpulse intervals (IPIs) of heartbeats is developed in this study. The proposed technique incorporates a finite monotonic increasing sequences generation mechanism of IPIs and a cyclic block encoding procedure that extracts a high number of entropic bits from each IPI. To validate the proposed technique, 89 ECG recordings including 25 healthy individuals in a laboratory environment, 20 from MIT-BIH Arrhythmia Database, and 44 cardiac patients from the clinical environment are considered. By applying the proposed technique on the ECG signals, atmost 16 random bits can be extracted from each heartbeat to generate 128-bit RBSs via concatenation of eight consecutive IPIs. And the randomness and distinctiveness of generated 128-bit RBSs are measured based on the National Institute of Standards and Technology statistical tests and hamming distance, respectively. From the experimental results, the generated 128-bit RBSs from both healthy subjects and patients can potentially be used as keys for encryption or entity identifiers to secure WBSNs. Moreover, the proposed approach is examined to be up to four times faster than the existing heartbeat-based RBSs generation schemes. Therefore, the developed technique necessitates less processing time (0-8 s) in real-time health monitoring scenarios to construct 128-bit RBSs in comparisons with current methods.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据