期刊
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING
卷 3, 期 1, 页码 271-276出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.jece.2014.11.008
关键词
Ion imprinted polymer; Modified electrode; Anodic stripping voltammetry; Glassy carbon electrode
资金
- NSTRI
- Azad University Research Council
A glassy carbon electrode (GCE) modified with zinc ion-imprinted polymers (GC/IIP) was used for the determination of sub-nanomolar amounts of zinc in the tap water samples by means of anodic stripping voltammetry (ASV). The GC/IIP modified electrode revealed a significant improvement for zinc detection compared with the bare GCE. Zinc ion-imprinted polymers were synthesized by thermal polymerization and zinc ions were removed by leaching the IIP by HCl and after drying in the oven, utilized for the electrode modification. The potential was scanned from -0.3V to +0.4V versus Ag/AgCl and variable affecting parameters such as pH, deposition duration time, deposition potential and stirring speed were optimized for ASV detection. The resulting calibration curve exhibited a linear response within a concentration range of 5 x 10 (10) to 1 x 10 M-8 with a low detection limit of 0.5 nM. Finally, the method was successfully applied to the determination of water samples. (C) 2014 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据