期刊
ANNALS OF REHABILITATION MEDICINE-ARM
卷 39, 期 2, 页码 170-175出版社
KOREAN ACAD REHABILITATION MEDICINE
DOI: 10.5535/arm.2015.39.2.170
关键词
Ulnar neuropathies; Ultrasonography; Cross-sectional area; Cut-off value
Objective To determine the diagnostic cutoff values of ultrasonographic measurements in ulnar neuropathy at the elbow (UNE). Methods Twenty-five elbows of 23 patients (9 females, 16 males) diagnosed with UNE and 30 elbows of 30 healthy controls (15 females, 15 males) were included in our study. The ulnar nerve cross-sectional area (CSA) was measured at the Guyon canal, midforearm, and maximal swelling point (MS) around the elbow (the cubital tunnel inlet in healthy controls). CSA measurements of the ulnar nerve at each point, the Guyon canal-to-MS ulnar nerve area ratio (MS/G), and the midforearm-to-MS ulnar nerve ratio (MS/F) were calculated. Results Among the variables, only CSA at MS, MS/G, and MS/F displayed significant differences between the control and patient groups. The cutoff value for diagnosing UNE was 8.95 mm(2) for the CSA at MS (sensitivity 93.8%, specificity 88.3%), 1.99 for the MS/G (sensitivity 75.0%, specificity 73.3%), and 1.48 for the MS/F (sensitivity 93.8%, specificity 95.0%). Conclusion These findings may be helpful to diagnose UNE.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐