4.5 Article Proceedings Paper

Assessment of the JT-60SA divertor cryopump performance

期刊

FUSION ENGINEERING AND DESIGN
卷 136, 期 -, 页码 467-471

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.fusengdes.2018.02.099

关键词

Cryogenic condensation pump; Pumping speed; Heat load; Test particle Monte Carlo simulation

资金

  1. EURATOM research and training programme 2014-2018 [633053]
  2. EUROFusion HPC project VAC_ND

向作者/读者索取更多资源

The cryogenic pumping system is one of the key components that define the operational window of JT-60SA. It is envisaged to utilize condensation pumps that work at 3.8 K, and proper thermal shields cooled with water and 80 K gaseous helium are necessary to allow having them installed at short distance to the torus in order to exploit high pumping speeds. In this paper, one complete divertor cryopump unit in a 40 degrees sector is studied by Monte Carlo simulation. The pumping speeds of one cryopump unit for D-2 were found to be between 14.8 m(3)/s and 18.1 m(3)/s depending on the assumptions taken. In addition, the heat loads to the cryopump condensation pipes during steady state nominal operation, as well as the heat loads and transient behavior after massive gas injection events are assessed. The present design can fulfil the requirement of pumping, cooling and regeneration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。