4.4 Article

Flow of partially condensed R-134a vapour through an adiabatic capillary tube

期刊

FLOW MEASUREMENT AND INSTRUMENTATION
卷 59, 期 -, 页码 1-7

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.flowmeasinst.2017.11.004

关键词

Adiabatic; Capillary tube; Refrigerant; R-134a

向作者/读者索取更多资源

This paper presents an experimental study of an adiabatic flow of R-134a through a capillary tube. The paper discusses the details of experimental facility for testing a capillary tube with sub-cooled and two phase inlet conditions of R-134a. The effect of diameter, capillary length, inlet refrigerant quality and inlet pressure on mass flow rate were investigated. The experiments for testing the capillary tubes were proceeded by an integrity test. The vapour quality varied from 0.05 to 0.25. All the experiments were done by varying the pressure from 655 to 724 kPa. The effect of two phase inlet conditions on mass flow rate of R-134a through an adiabatic capillary tube is observed. A correlation to predict the mass flow rate of refrigerant flowing through an adiabatic capillary tube is proposed for two phase inlet conditions. The proposed correlation predicts the measured data with an error band of 25%.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据