4.7 Article

Association of low-moderate urine arsenic and QT interval: Cross-sectional and longitudinal evidence from the Strong Heart Study

期刊

ENVIRONMENTAL POLLUTION
卷 240, 期 -, 页码 894-902

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.envpol.2018.04.129

关键词

Arsenic; QT interval; Electrocardiology; Ventricular repolarization; Cardiovascular disease; Longitudinal cohort

资金

  1. National Institute of Environmental Health Sciences [1R01ES025216, R01ES021367, 5P30ES009089, P42ES010349]
  2. National Heart, Lung, and Blood Institute [HL41642, HL41652, HL41654, HL65521, 5T32HL007024]

向作者/读者索取更多资源

Epidemiologic studies suggest that chronic exposure to arsenic is related to cardiovascular disease (CVD), but the pathophysiological link remains uncertain. We evaluated the association of chronic low moderate arsenic exposure and arsenic metabolism with baseline difference and annual change in ECG measures (QT interval, JT interval, PR interval, QRS duration, and QT dispersion) using linear mixed models in the Strong Heart Study main cohort (N = 1174, median age 55 years) and family study (N = 1695 diabetes-free, median age 36 years). At baseline, arsenic exposure was measured as the sum of inorganic and methylated species in urine (Sigma As) and arsenic metabolism was measured as the relative percentage of arsenic species. Median Sigma As and Bazett heart rate-corrected QT interval (QTc) were 8.6 mu g/g creatinine and 424 ms in the main cohort and 4.3 gig and 414 ms in the family study, respectively. In the main cohort, a comparison of the highest to lowest Sigma As quartile (>14.4 vs. <5.2 mu g/g creatinine) was associated with a 5.3 (95% CI: 1.2, 9.5) ms higher mean baseline QTc interval but no difference in annual change in QTc interval. In the family study, a comparison of the highest to lowest quartile (>7.1 vs. <2.9 mu g/g creatinine) was associated with a 3.2 (95% Cl: 0.6, 5.7) ms higher baseline QTc interval and a 0.6 (95% CI: 0.04, 1.2) ms larger annual increase in QTc interval. Associations with JTc interval were similar but stronger in magnitude compared to QTc interval. Arsenic exposure was largely not associated with PR interval, QRS duration or QT dispersion. Similar to arsenic exposure, a pattern of lower %MMA and higher %DMA was associated with longer baseline QTc interval in both cohorts and with a larger annual change in QTc interval in the family study. Chronic low-moderate arsenic exposure and arsenic metabolism were associated with prolonged ventricular repolarization. (C) 2018 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据