4.8 Article

Cardiopulmonary effects of overnight indoor air filtration in healthy non-smoking adults: A double-blind randomized crossover study

期刊

ENVIRONMENT INTERNATIONAL
卷 114, 期 -, 页码 27-36

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.envint.2018.02.010

关键词

Air pollution; Indoor air quality; Air filtration; Airway mechanics; Thrombosis; Impulse oscillometry

资金

  1. National Natural Science Foundation of China [51420105010, 51521005]
  2. Duke University Integrated Toxicology and Environmental Health Program
  3. Duke University Graduate School

向作者/读者索取更多资源

Background: More than 90% of the world's population lives in areas where outdoor air pollution levels exceed health-based limits. In these areas, individuals may use indoor air filtration, often on a sporadic basis, in their residences to reduce exposure to respirable particles (PM2.5). Whether this intervention can lead to improvements in health outcomes has not been evaluated. Methods: Seventy non-smoking healthy adults, aged 19 to 26 years, received both true and sham indoor air filtration in a double-blinded randomized crossover study. Each filtration session was approximately 13 h long. True and sham filtration sessions were separated by a two-week washout interval. The study was carried out in a suburb of Shanghai. Results: During the study period, outdoor PM2.5 concentrations ranged from 18.6 to 106.9 mu g/m(3), which overlapped with levels measured in Western Europe and North America. Compared to sham filtration, true filtration on average decreased indoor PM2.5 concentration by 72.4% to 10.0 mu g/m(3) and particle number concentration by 59.2% to 2316/cm(3). For lung function measured immediately after the end of filtration, true filtration significantly lowered airway impedance at 5 Hz (Z(5)) by 7.1% [95% CI: 2.4%, 11.9%], airway resistance at 5 Hz (R-5) by 7.4% [95% CI: 2.4%, 12.5%], and small airway resistance (R-5-R-20) by 20.3% [95% CI: 0.1%, 40.5%], reflecting improved airway mechanics especially for the small airways. However, no significant improvements for spirometry indicators (FEV1, FVC) were observed. True filtration also significantly lowered von Willebrand factor (VWF) by 26.9% [95% CI: 7.3%, 46.4%] 24 h after the end of filtration, indicating reduced risk for thrombosis. Stratified analysis in male and female participants showed that true filtration significantly decreased pulse pressure by 3.3% [95% CI: 0.8%, 7.4%] in females, and significantly reduced VWF by 42.4% [95% CI: 17.4%, 67.4%] and interleukin-6 by 22.6% [95% CI: 0.4%, 44.9%] in males. Effect modification analyses indicated that filtration effects in male and female participants were not significantly different. Conclusion: A single overnight residential air filtration, capable of reducing indoor particle concentrations substantially, can lead to improved airway mechanics and reduced thrombosis risk.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据