4.7 Article

An experimental investigation into the comparative hygrothermal performance of wall panels incorporating wood fibre, mineral wool and hemp-lime

期刊

ENERGY AND BUILDINGS
卷 165, 期 -, 页码 76-91

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/J.enbuild.2018.01.028

关键词

Mineral Wool; Wood Fibre; Biond; U-value; Bio-based insulation materials; Hemp-lime; Thermal conductivity; Moisture

资金

  1. European Union [ECO/12/332972/SI2.653796-HEMPSEC]
  2. EPSRC [EP/L005689/1] Funding Source: UKRI
  3. Engineering and Physical Sciences Research Council [EP/L005689/1] Funding Source: researchfish

向作者/读者索取更多资源

Three wall panels of identical calculated U-value were simultaneously assessed in a large dual environmental chamber under a number of steady state and dynamic hygrothermal boundary conditions. This study used large-scale wall elements under identical controlled conditions in order to eliminate uncontrollable variables normally encountered in full-scale studies. The following panels were tested: Mineral Wool Panel, Wood Fibre Panel and the Biond Panel (an assembly of wood fibre and hemp-lime). Within the limits of the error range of the calculation, the measured U-value was same for all test panels when assessed under steady state and dynamic hygrothermal boundary conditions. It was however observed that in a boundary condition simulating intermittent heating, the Biond panel showed the highest heat storing and releasing capability whereas the Mineral Wool Panel showed the lowest. In terms of moisture management, the Biond panel exhibited the highest moisture dampening ability within the panel structure. Higher thermal and hygric inertia of the Biond panel may be useful in mitigating overheating of dwellings and reducing interstitial condensation. (C) 2018 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据