4.6 Article

Predictors of Intubation in Patients With Acute Hypoxemic Respiratory Failure Treated With a Noninvasive Oxygenation Strategy

期刊

CRITICAL CARE MEDICINE
卷 46, 期 2, 页码 208-215

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0000000000002818

关键词

acute respiratory failure; high-flow nasal cannula; high-flow oxygen therapy; intubation; noninvasive ventilation

向作者/读者索取更多资源

Objectives: In patients with acute hypoxemic respiratory failure, noninvasive ventilation and high-flow nasal cannula oxygen are alternative strategies to conventional oxygen therapy. Endotracheal intubation is frequently needed in these patients with a risk of delay, and early predictors of failure may help clinicians to decide early. We aimed to identify factors associated with intubation in patients with acute hypoxemic respiratory failure treated with different noninvasive oxygenation techniques. Design: Post hoc analysis of a randomized clinical trial. Setting: Twenty-three ICUs. Patients: Patients with a respiratory rate greater than 25 breaths/min and a Pao(2)/Fio(2) ratio less than or equal to 300mm Hg. Intervention: Patients were treated with standard oxygen, high-flow nasal cannula oxygen, or noninvasive ventilation. Measurement and Main Results: Respiratory variables one hour after treatment initiation. Under standard oxygen, patients with a respiratory rate greater than or equal to 30 breaths/min were more likely to need intubation (odds ratio, 2.76; 95% CI, 1.13-6.75; p = 0.03). One hour after high-flow nasal cannula oxygen initiation, increased heart rate was the only factor associated with intubation. One hour after noninvasive ventilation initiation, a Pao(2)/Fio(2) ratio less than or equal to 200 mm Hg and a tidal volume greater than 9 mL/kg of predicted body weight were independent predictors of intubation (adjusted odds ratio, 4.26; 95% CI, 1.62-11.16; p = 0.003 and adjusted odds ratio, 3.14; 95% CI, 1.22-8.06; p = 0.02, respectively). A tidal volume above 9 mL/kg during noninvasive ventilation remained independently associated with 90-day mortality. Conclusions: In patients with acute hypoxemic respiratory failure breathing spontaneously, the respiratory rate was a predictor of intubation under standard oxygen, but not under high-flow nasal cannula oxygen or noninvasive ventilation. A Pao(2)/Fio(2) below 200mm Hg and a high tidal volume greater than 9mL/kg were the two strong predictors of intubation under noninvasive ventilation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据