Accuracy of Invasive and Noninvasive Parameters for Diagnosing Ventilatory Overassistance During Pressure Support Ventilation*

期刊

CRITICAL CARE MEDICINE
卷 46, 期 3, 页码 411-417

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0000000000002871

关键词

data accuracy; diagnosis; pressure support ventilation; respiration; artificial; methods; respiration; artificial; utilization; work of breathing

资金

  1. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (Fapesp) [2012/09170-3, 2010/08947-9]
  2. FAPESP - Fundacao de Amparo a Pesquisa do Estado de Sao Paulo

向作者/读者索取更多资源

Objective: Evaluate the accuracy of criteria for diagnosing pressure overassistance during pressure support ventilation. Design: Prospective clinical study. Setting: Medical-surgical ICU. Patients: Adults under mechanical ventilation for 48 hours or more using pressure support ventilation and without any sedative for 6 hours or more. Overassistance was defined as the occurrence of work of breathing less than 0.3 J/L or 10% or more of ineffective inspiratory effort. Two alternative overassistance definitions were based on the occurrence of inspiratory esophageal pressure-time product of less than 50 cm H2O s/min or esophageal occlusion pressure of less than 1.5 cm H2O. Interventions: The pressure support was set to 20 cm H2O and decreased in 3-cm H2O steps down to 2 cm H2O. Measurements and Main Results: The following parameters were evaluated to diagnose overassistance: respiratory rate, tidal volume, minute ventilation, peripheral arterial oxygen saturation, rapid shallow breathing index, heart rate, mean arterial pressure, change in esophageal pressure during inspiration, and esophageal and airway occlusion pressure. In all definitions, the respiratory rate had the greatest accuracy for diagnosing overassistance (receiver operating characteristic area = 0.92; 0.91 and 0.76 for work of breathing, pressure-time product and esophageal occlusion pressure in definition, respectively) and always with a cutoff of 17 incursions per minute. In all definitions, a respiratory rate of less than or equal to 12 confirmed overassistance (100% specificity), whereas a respiratory rate of greater than or equal to 30 excluded overassistance (100% sensitivity). Conclusion: A respiratory rate of 17 breaths/min is the parameter with the greatest accuracy for diagnosing overassistance. Respiratory rates of less than or equal to 12 or greater than or equal to 30 are useful clinical references to confirm or exclude pressure support overassistance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据