4.7 Article

Tensile creep and cracking potential of high performance concrete internally cured with super absorbent polymers at early age

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 165, 期 -, 页码 451-461

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2017.12.136

关键词

High performance concrete; Early age; Internal curing; Super absorbent polymers; Tensile creep; Autogenous shrinkage; Restrained stress; Cracking potential

资金

  1. National Natural Science Foundation of China [51578215]
  2. Fundamental Research Funds for Central Universities [2017B12614, 20178652X14, 2017B41114]
  3. Qing Lan Project of Jiangsu Province
  4. Postgraduate Research & Practice Innovation Program of Jiangsu Province [KYCX17_0478, SJCX17_0143]

向作者/读者索取更多资源

High performance concrete (HPC) has been extensively applied in practice. However, the water-to-cement (w/c) ratio of this concrete is low, high temperature rise and high self-desiccation will occur, and both of which can increase the cracking potential of HPC at early age and then decrease the service life of concrete structures. Therefore, super absorbent polymers (SAPs) are applied in HPC as an internal curing (IC) agent. Although the autogenous shrinkage, relative humidity, and stress relaxation of concrete internally cured with SAPs have been studied, investigations on the influence of SAPs on the tensile creep and cracking potential of HPC are still lacking. In present study, the influence of SAPs as an IC agent on the temperature, autogenous shrinkage, restrained stress, basic tensile creep, and cracking potential of HPC were simultaneously studied by Temperature Stress Test Machine. Test results and corresponding analysis showed that: (1) the adiabatic temperature rise of HPC was 27.6, 29.3, 31.0, and 34.9 degrees C and increased with the increase of amount of SAPs; (2) the rate of restrained tensile stress of HPC was 1.7, 1.5,1.4, and 1.2 MPa/day and decreased with the increase of amount of SAPs; (3) the specific basic tensile creep of HPC at the age when the restrained specimen of mixture SAP-0 cracked was 45, 23, 13, and 7 ge/MPa and decreased with the increase of amount of SAPs; (4) a model for predicting the basic tensile creep compliance function of HPC considering the influence of amount of SAPs was proposed; (5) the cracking potential of HPC which was based on the integrated criterion decreased with the increase of amount of SAPs. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据