Recent laboratory experiments have demonstrated the superior performance (high stiffness, load carrying capacity and ductility) of bolt shear connectors embedded in the pockets of cementitious grout compared to conventional fasteners (e.g. screws) for developing composite action between steel beams and timber slabs. Accordingly, this paper investigates the structural behaviour of steel-timber composite (STC) joints with bolt connectors embedded in grout pockets (BCGP) using 3-D continuum-based finite element (FE) models. Following validation of the FE models against available push-out test data, they are used to conduct a parametric study that elucidates the influences of the compressive strength of the grout, the yield strength and size of the bolt shear connectors, the size of the grout pockets and the thickness of the steel profile flange on the load-slip behaviour, service stiffness, peak load-carrying capacity and failure modes of STC joints with BCGP. Simple formulae for the stiffness and load carrying capacity of the STC joints with BCGP are derived from linear regression of the results of the parametric study. (C) 2018 Elsevier Ltd. All rights reserved.