4.8 Article

Newer-Generation Ultrathin Strut Drug-Eluting Stents Versus Older Second-Generation Thicker Strut Drug-Eluting Stents for Coronary Artery Disease Meta-Analysis of Randomized Trials

期刊

CIRCULATION
卷 138, 期 20, 页码 2216-2226

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.118.034456

关键词

coronary artery disease; drug-eluting stents; percutaneous coronary intervention; stents; treatment outcome

向作者/读者索取更多资源

BACKGROUND: Contemporary second-generation drug-eluting stents (DES) have superior efficacy and safety in comparison with early-generation stents in patients undergoing percutaneous coronary intervention, in part, related to their thinner struts. Whether newer-generation ultrathin DES further improve clinical outcomes in comparison with older second-generation thicker strut DES is unknown. METHODS: We searched PubMed, Embase, and Cochrane Central Register of Controlled Trials for randomized clinical trials that compared newer-generation ultrathin strut DES (defined as strut thickness <70 mu m) versus thicker strut second-generation DES and reported clinical outcomes. The primary outcome was target lesion failure (composite of cardiovascular death, target vessel myocardial infarction or ischemia-driven target lesion revascularization) evaluated at 1-year follow-up. Tests for subgroup effects based on the ultrathin strut DES type and the comparator DES type were performed by using meta-regression analysis. RESULTS: We identified 10 trials that randomly assigned 11 658 patients and evaluated 3 newer-generation ultrathin strut DES: Orsiro stent (60 mu m), MiStent (64 mu m), and BioMime (65 mu m). In comparison with thicker strut second-generation DES, newer-generation ultrathin strut DES were associated with a 16% reduction in target lesion failure (relative risk, 0.84; 95% CI, 0.72-0.99) driven by less myocardial infarction (relative risk, 0.80; 95% CI, 0.65-0.99). Ultrathin strut DES were also associated with qualitatively lower rates of any stent thrombosis (relative risk, 0.72; 95% CI, 0.51-1.01). Tests for subgroup effects based on the ultrathin strut DES type (P=0.58) and the comparator DES type (P=0.98) were not significant, suggesting consistent outcomes across the 3 ultrathin strut DES and with the different DES comparators. CONCLUSIONS: In patients undergoing percutaneous coronary intervention, newer-generation ultrathin strut DES further improve 1-year clinical outcomes in comparison with contemporary thicker strut second-generation DES.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据