3.8 Article

Heat Transfer and Friction Factor of Al2O3 Nanofluid Flow in a Double Pipe U-Tube Heat Exchanger and with Longitudinal Strip Inserts: An Experimental Study

期刊

JOURNAL OF NANOFLUIDS
卷 4, 期 3, 页码 293-301

出版社

AMER SCIENTIFIC PUBLISHERS
DOI: 10.1166/jon.2015.1161

关键词

Nanofluid; Heat Transfer; Friction Factor; Longitudinal Strip Inserts

向作者/读者索取更多资源

Heat transfer and friction factor of Al2O3 nanofluid flow in a double pipe U-tube heat exchanger fitted with longitudinal strip inserts are estimated experimentally. Nanofluid is circulated inside the tube and hot water is circulated in the annulus of double pipe U-tube heat exchanger. The experimental data is generated with water and nanofluid in the Reynolds number range of 3000 to 30000, in the volume concentration ranging from 0 to 0.03% and longitudinal strip inserts of aspect ratios 1, 2, 4 and 12. The results indicates that the Nusselt number and friction factor of entire pipes for 0.03% concentration of nanofluid with longitudinal strip inserts of aspect ratio 1 enhances by 47.35% and 1.21 times compared to water. However, the pressure drop in the pipe increases with the increases of nanoparticle volume concentration and aspect ratio of the inserts. The empirical correlations for the Nusselt number and friction factor are obtained as functions of the Reynolds number, Prandtl number, volume concentration and aspect ratio.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据