Fire Spread Caused by Combustible Facades in Japan

期刊

FIRE TECHNOLOGY
卷 52, 期 4, 页码 1081-1106

出版社

SPRINGER
DOI: 10.1007/s10694-015-0535-5

关键词

Facade fire; Combustible facade; Fire spread; Temperature; Incident heat flux

向作者/读者索取更多资源

With regard to fire safety for exterior walls of a building, fire-resistance performance is considered, according to the current building standard law of Japan. And it was revealed that the fire safety is not specifically regulated from the viewpoint of reaction-to-fire performance, such as fire propagation caused by combustible materials or products which are installed on the exterior side of fire-resistant load-bearing walls. Actual fire issues in the world have shown that massive fa double dagger ade fire could occur at the exterior side of building wall even when the wall itself is fire-resistant. In previous studies of the authors, a test method of fa double dagger ade fire was tentatively proposed for evaluating the vertical fire propagation over an external wall within the same building. Furthermore, especially at the high-density residential areas in Japan, fire spreading would occur mostly from window to window between adjacent buildings, while walls are not burning by fa double dagger ade fire. But in case of combustible fa double dagger ades, such as insulating materials, combustible coating, or even sandwich panel are installed on the wall surface, once they are ignited, fa double dagger ade fire would occur and accelerate both the fire propagation in the same building and the fire spreading to the adjacent building. In this paper, results of fire tests on combustible fa double dagger ades are discussed from the viewpoints of both vertical fire spread along fa double dagger ades and fire spread between adjacent buildings assuming the densely populated residential area in Japan. The tentative criteria were determined based on the time to reach 500A degrees C and duration time exceeding 500A degrees C on fa double dagger ade surface for vertical fire spread along fa double dagger ade. As for intensively burned cases, at 2500 mm height from upper edge of the opening, specimens of exterior thermal insulation system with 200-mm thick expanded polystyrene (EPS), aluminum composite panel with polyethylene core and wooden fa double dagger ade without fire-retardant treatment continued exceeding 500A degrees C for 3.1 min, 5.7 min, and 3.6 min, respectively, that were longer duration compared with specimens of resin painting (approximately 1 min). On the other hand, the another tentative criteria were determined for horizontal fire spread to an adjacent building based on the duration time exceeding the calibration test's peak incident heat flux on opposite surface 2000 mm from fa double dagger ade surface for horizontal fire spread to an adjacent building. At 500 mm height from upper edge of the opening, specimens of exterior thermal insulation system with high-density 100-mm thick EPS and wooden fa double dagger ade without fire-retardant treatment continued exceeding the peak incident heat flux of calibration test for 13.1 min and 13.6 min, respectively, while one specimen of resin painting and aluminum composite panel with polyethylene core continued for shorter duration of 4.2 min and 5.8 min, respectively, even though they showed relatively high peak fa double dagger ade surface temperatures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据