期刊
FIRE SAFETY JOURNAL
卷 71, 期 -, 页码 287-298出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.firesaf.2014.11.025
关键词
Hybrid ventilation; Longitudinal ventilation; Point ventilation; Tunnel fire; Smoke height; Model experiment
We examined the exhaust performance of a hybrid ventilation strategy for maintaining a safe evacuation environment for tunnel users in a tunnel fire. The hybrid ventilation strategy combines the longitudinal ventilation strategy with the point ventilation strategy which is a type of transverse ventilation strategy. The model tunnel developed by this study was scaled to 1/5 the size of a full-scale tunnel. The model-scale experiment was performed taking into consideration Froude's law of similarity. Measurement items were the distribution of temperature and concentration of smoke inside the tunnel, longitudinal wind velocity, mass flow of smoke in the point ventilation duct, and the heat release rate of the fire source. The following main conclusions were obtained. The smoke height was constant even when varying the extraction rate of smoke from the ceiling vent. The backlayering length and critical velocity of the smoke flow in the hybrid strategy could be predicted by the methodology developed by using the longitudinal strategy. The hybrid strategy maintained a safe evacuation environment on both sides of the tunnel fire. (C) 2014 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐