4.8 Article

Multi-parametric rigid and flexible, low-cost, disposable sensing platforms for biomedical applications

期刊

BIOSENSORS & BIOELECTRONICS
卷 102, 期 -, 页码 668-675

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2017.10.038

关键词

PCB electrode; Ion sensors; Flexible; Multi-parametric; Potentiometric sensors

资金

  1. UK Engineering and Physical Sciences Research Council (EPSRC) [EP/L014149/1]
  2. EPSRC [EP/L014149/1, EP/J021199/1] Funding Source: UKRI
  3. Engineering and Physical Sciences Research Council [EP/J021199/1, EP/L014149/1] Funding Source: researchfish

向作者/读者索取更多资源

The measurement of Na+, K+ and H+ is essential in medicine and plays an important role in the assessment of tissue ischemia. Microfabrication, inkjet- and screen-printing can be used for solid contact ion selective electrodes (ISE) realization; these, however, can be non-standardized, costly and time consuming processes. We present the realization of ISEs on post-processed electrodes fabricated via standardized printed circuit board (PCB) manufacturing techniques. In vitro results are presented from two rigid platforms (32 ISEs) for liquid sample dip-stick measurements and two flexible platforms (6 and 32 ISEs) for post-surgical intestinal tissue monitoring, each with a common reference electrode (RE). These are combined with optimized tetrapolar bioimpedance sensors for tissue ischemia detection. Both electroless and hard gold PCB finishes are examined. Apart from the electroless rigid platform, the rest demonstrated comparable and superior performance, with the pH sensors demonstrating the greatest deviation; the flexible hard gold platform achieved a sensitivity 4.6 mV/pH and 49.2 mV/pH greater than the electroless flexible and rigid platforms, respectively. The best overall performance was achieved with the hard gold flexible platform with sensitivities as large as 73.4 mV/pH, 56.3 mV/log [Na+], and 57.4 mV/log [K+] vs. custom REs on the same substrate. Simultaneous measurement of target analytes is demonstrated with test solutions and saliva samples. The results demonstrate superior performance to other PCB-based pH sensors and Na+ and K+ PCB-based sensors with comparable performance to potentiometric sensors fabricated with other techniques, paving the way towards mass-produced, low-cost, disposable, multi-parametric chemical sensing diagnostic platforms.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据