4.8 Article

A new carbon paste electrode modified with MWCNTs and nano-structured molecularly imprinted polymer for ultratrace determination of trimipramine: The crucial effect of electrode components mixing on its performance

期刊

BIOSENSORS & BIOELECTRONICS
卷 111, 期 -, 页码 27-33

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2018.03.061

关键词

Carbon nanotube; Carbon paste electrode; Imprinted polymer; Trimipramine; Voltammetric sensor; Nanoparticles

资金

  1. Institute of Electrochemistry, Tehran University, Iran

向作者/读者索取更多资源

A novel carbon nanocomposite paste electrode was prepared and used as a voltammetric sensor for ultratrace determination of trimipramine (TRI) which currently used for the treatment of psychiatric disorders. For this aim, nanoparticles of molecularly imprinted polymer (MIP), synthesized by precipitation polymerization method, and multi-walled carbon nanotubes (MWCNTs) were embedded in a nanocomposite paste electrode. The nanocomposite mixing style demonstrated a significant influence on the final electrode performance. The sensor exhibited linear response range of 1.0 x 10(-10)-2.5 x 10(-8) mol L-1 and very high sensitivity of 2131 mu A mu mol L-1. The lower detection limit of the sensor was calculated to be 4.5 x 10(-11) mol L-1 (S/N = 3). This sensor was applied successfully for highly selective determination of TRI in pharmaceutical formulations, urine and serum samples without applying any sample pretreatment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据