4.8 Article

Assessing active and passive effects of fa ade building integrated photovoltaics/thermal systems: Dynamic modelling and simulation

期刊

APPLIED ENERGY
卷 209, 期 -, 页码 355-382

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2017.09.039

关键词

Building integrated photovoltaic thermal system; Dynamic simulation modelling; Multi-floor building; Energy performance analysis

资金

  1. Building Integration of Solar Thermal Systems, BISTS of European COST (Cooperation in Science and Technology), Transport and Urban Development (TUD) [Action TU1205]

向作者/读者索取更多资源

This paper analyses the integration of air open-loop photovoltaic thermal systems on the fa ade of high-rise buildings, with a special focus on their active and passive effects. The system energy performance and its impact on the building heating and cooling demands and electrical production are assessed through a new dynamic simulation model. The developed numerical model of the proposed system, based on a detailed transient finite difference thermal network, is verified by comparing its outcomes to experimental results. With the aim to carry out whole building energy performance analyses, the model is implemented in a dynamic simulation tool for the building energy performance assessment, called DETECt 2.3, and suitably modified to analyse the main building integration energy issues. To assess the potentiality of the numerical model and the feasibility of the investigated system, a comprehensive case study relative to a multi-floor high rise office building located in several European climate zones is developed. A comparative and parametric analysis is also carried out with the aim to evaluate the system active and passive effects as a function of the building height. Simulation results show that by using building integrated air open-loop photovoltaic thermal systems, an interesting percentage reduction of the heating demand can be obtained. Both passive and active effects contribute to the variation of the thermal and electrical efficiencies. For the investigated weather zones, the innovative system leads to a reduction of the final energy consumptions ranging from 56.8 to 104.4%, approaching the nearly or net positive zero energy building target in the southern climate. Finally, the proposed analysis also aims to show the main implications linked to the design of the system, to be carefully taken into consideration by designers and stakeholders in case of new buildings or renovations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据