4.8 Article Proceedings Paper

Optimal placement, sizing, and daily charge/discharge of battery energy storage in low voltage distribution network with high photovoltaic penetration

期刊

APPLIED ENERGY
卷 226, 期 -, 页码 957-966

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2018.06.036

关键词

Photovoltaic (PV); Battery energy storage system (BESS); Distribution network; Optimal planning and operation; High penetration

向作者/读者索取更多资源

Proper installation of rooftop photovoltaic generation in distribution networks can improve voltage profile, reduce energy losses, and enhance the reliability. But, on the other hand, some problems regarding harmonic distortion, voltage magnitude, reverse power flow, and energy losses can arise when photovoltaic penetration is increased in low voltage distribution network. Local battery energy storage system can mitigate these disadvantages and as a result, improve the system operation. For this purpose, battery energy storage system is charged when production of photovoltaic is more than consumers' demands and discharged when consumers' demands are increased. Since the price of battery energy storage system is high, economic, environmental, and technical objectives should be considered together for its placement and sizing. In this paper, optimal placement, sizing, and daily (24 h) charge/discharge of battery energy storage system are performed based on a cost function that includes energy arbitrage, environmental emission, energy losses, transmission access fee, as well as capital and maintenance costs of battery energy storage system. All simulations are carried out in DIgSILENT and MATLAB linked together. Results show that by using the proposed approach, overvoltage and energy losses are decreased, reverse power flow is prevented, environmental emission is reduced, and economic profit is maximized.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据