4.8 Article

A Ratiometric Fluorescent Bioprobe Based on Carbon Dots and Acridone Derivate for Signal Amplification Detection Exosomal microRNA

期刊

ANALYTICAL CHEMISTRY
卷 90, 期 15, 页码 8969-8976

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.8b01143

关键词

-

资金

  1. Natural Science Foundation of Fujian Province [2017J07001, 2017J01226]
  2. Fujian Science and Technology Innovation Joint Found Project [2016Y9050]
  3. Medical Elite Cultivation Program of Fujian, PRC [2014-ZQN-ZD-26]
  4. National Natural Science Foundation of China [21375017, 81372092, 81671930, 21475026, 21622502]
  5. Foundation of Fujian Provincial Department of Science Technology [2015Y0059]

向作者/读者索取更多资源

Recently, sensitive and selective detection of exosomal microRNAs (miRNAs) has been garnering significant attention, because it is related to many complex diseases, including cancer. Herein, we report a ratiometric fluorescent bioprobe based on DNA-labeled carbon dots (DNA-CDs) and 5,7-dinitro-2-sulfo-acridone (DSA) coupling with the target-catalyzing signal amplification for the detection of exosomal miRNA-21. There was high fluorescence resonance energy transfer (FRET) efficiency between carbon dots (CDs) and DSA when the bioprobe was assembled. However, in the presence of the target, with disassembling of the fluorescent bioprobe, the fluorescence intensities of CDs and DSA were changed simultaneously. Because of the ratio of dual fluorescence intensities, this ratiometric fluorescent bioprobe was able to cancel out environmental fluctuations by calculating emission intensity ratio at two different wavelengths, being robust and stable enough for detection of exosomal miRNA-21. In addition, we displayed that a single miRNA-21 can catalyze the disassembly of multiple CDs with DSA theoretically, yielding significant change in the fluorescence ratio for the detection of miRNA-21. With this signal amplification strategy, the limit of detection was as low as 3.0 fM. Furthermore, because of the introduction of lock nucleic acid to mediate the strand displacement reaction, the selectivity of this strategy was improved remarkably, even against single base mismatch sequence. More importantly, our strategy could monitor the dynamic change of exosomal miRNA-21, which maybe becomes a potential tool to distinguish cancer exosomes and nontumorigenic exosomes. In a short, this ratiometric fluorescence bioprobe possessed high stability, sensitivity and selectivity coupling with ease of operation and cost efficiency, leading to great potential for wide application.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据