4.5 Article

A molecularly-imprinted-electrochemical-sensor modified with nano carbon-dots with high sensitivity and selectivity for rapid determination of glucose

期刊

ANALYTICAL BIOCHEMISTRY
卷 555, 期 -, 页码 42-49

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.ab.2018.06.004

关键词

Carbon dots; Molecularly imprinted electrochemical sensor; Glucose; 3-Aminobenzeneboronic acid

资金

  1. National Natural Science Foundation of China [31601549, U1507115]
  2. Natural Science of Jiangsu Province [BK20161362, 20160500]
  3. Natural Science of Jiangsu Education [16KJB150045]
  4. h-Level Personnel Training Project of Jiangsu Province [BRA2016142]
  5. Scientific Research Foundation for Advanced Talents
  6. China Postdoctoral Science Foundation [2016M601747]
  7. Qing Lan Project of the Higher Education Institutions of Jiangsu Province
  8. Senior Talent Start-up Funds of Jiangsu University of Technology and Training Program of Jiangsu Excellent Talents in Higher Vocational College [2017GRFX066]

向作者/读者索取更多资源

In this work, a novel molecularly imprinted electrochemical sensor (MIECS) based on a glassy carbon electrode (GCE) modified with carbon dots (CDs) and chitosan (CS) for the determination of glucose was proposed for the first time. The use of the environmental-friendly CDs and CS as electrode modifications improved the active area and electron-transport ability substantially, while 3-aminobenzeneboronic acid was used as a functional monomer and glucose as template for the fabrication of molecularly imprinted polymer (MIP) film to detect glucose via differential pulse voltammetry. Transmission electron microscope, Fourier transform infrared spectroscopy, energy dispersive x-ray spectrometry, cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were applied to characterize the fabricated sensor. Experimental conditions such as molar ratio of functional monomer to template, volume ratio of CDs to CS, incubation time and elution time were optimized. By using glucose as a model analyte, the MIECS had two assay ranges of 0.5-40 mu M and 50-600 mu M, and fairly low limit of detection (LOD) of 0.09 mu M (S/N = 3) under the optimized conditions. The MIECS also exhibited excellent selectivity, good reproducibility, and stability. The proposed sensor was successfully applied to a preliminary test for glucose analysis in real human blood serum samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据