Accurate anisotropy recovery from fluorophore mixtures using Multivariate Curve Resolution (MCR)

期刊

ANALYTICA CHIMICA ACTA
卷 1000, 期 -, 页码 132-143

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2017.11.031

关键词

Fluorescence; Anisotropy; Multidimensional; Standards; Chemometrics

资金

  1. 'EMBARK Initiative' Postgraduate Scholarship from Irish Research Council [GOIPG/2015/3826]
  2. Irish Research Council (IRC) [GOIPG/2015/3826] Funding Source: Irish Research Council (IRC)

向作者/读者索取更多资源

Anisotropy resolved multidimensional emission spectroscopy (ARMES) provides valuable insights into multi-fluorophore systems like proteins that have complex overlapping emission bands. The method combines multidimensional fluorescence, anisotropy, and chemometrics to facilitate the differentiation of fluorophores with very similar emission properties. Here, we address the critical issue of standardizing the chemometric methods required to accurately extract spectral and anisotropy information from fluorophore mixtures using two standard sample sets: perylene in glycerol, and a mixture of Erythrosin B and Phloxine B with overlapping emission but different anisotropies. We show for the first time how to accurately model component anisotropy using Multivariate Curve Resolution (MCR) from data collected using total synchronous fluorescence scan (TSFS) and Excitation Emission Matrix (EEM) measurement methods. These datasets were selected to avoid the presence of inner filter effects (IFE) or Forster resonance energy transfer (FRET) that would depolarize fluorescence emission or reduce data tri-linearity. This allowed the non-trilinear TSFS data to yield accurate component anisotropy data once modelled using the correct data augmentation strategy, however, the EEM data proved to be more accurate once optimal constraints (non-negativity and correspondence among species) were employed. For perylene (S-2) and Phloxine B which both have very weak anisotropy (<0.06), while the spectral recovery was excellent, the modelled anisotropy values were reasonably accurate (+/- 20% of the real value) because of large relative noise contributions. However, for perylene (S-1) and Erythrosin B which have large (>0.2) anisotropies, bilinear and trilinear EEM models built using a total tri-linearity constraint, yielded solutions without any rotational ambiguities and very accurate (+/- 4% of real value) anisotropy values. These sample systems thus provide simple and robust test systems for validating the spectral measurement and chemometric data analysis elements of ARMES. (c) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据